NPS-8H20-ATS-2 Network Power Switch PDU + Automatic Transfer Switch 208V 8 Outlet

NPS-8H20-ATS-2 Network Power Switch PDU + ATS 20A 208V (8)IEC C13

Remote Reboot (8) IEC C13 Switched Outlets, 208V AC, Dual 20Amp Automatic Transfer Switch (ATS)

SKU:  NPS-8H20-ATS-2
Price: $1,057.00 (USD)

Accessories Included:

  • Quick Start Guide
  • DX9F-DTE-RJ - Adapter, DB-9F to RJ-45
  • Network Cable, Cat 5e, 7 ft.
  • Power Cable Retainer Kit
Dual Input: Primary + Secondary
Voltage: 200-240V AC
Current: (2) 20A (16A Derated)
Connectors: (2) IEC C20
Dual Output
Voltage: 200-240V AC
Current: (2) 20A (16A Derated)
Outlets: (8) IEC C13

 

WTI's NPS-8H20-ATS-2 network power switch PDU with automatic transfer switching is the perfect solution for critical network installations needing remote power control and power supply redundancy on 208V AC equipment. Just connect the power cable of your switches, routers, firewalls or any other network device directly to the power outlets of the NPS-8H20-ATS-2 and you're ready for complete remote power on, off or reboot control plus automatic power transfer switching.

The NPS-8H20-ATS-2 includes a robust selection of security and monitoring features, including event and temperature alarms, to help minimize angry support calls and accidental shutdowns.

Automatic Transfer Switching

The NPS-8H20-ATS-2 has a built in power transfer switch for automatic fallback of supplied power. Any single power supply device can now have the redundancy of two power sources. The NPS-ATS powers all (8) outlets through the primary input power supply with the ability to automatically transfer the power load of all (8) outlets to the secondary line. Should the primary power supply line fail the NPS-ATS will detect the failure and switch to a secondary power supply line in less than 16 milliseconds.

Reboot Local & Remote Equipment!

Servers, routers, and other electronic equipment sometimes "lock-up," often requiring a service call to a remote site just to flip the power switch to perform a simple reboot. The NPS-8H20-ATS-2 gives you the ability to remote reboot and remote power cycle equipment from anywhere; just point your browser to the IP address of any NPS-8H20-ATS-2 unit, enter the secure user name and password, and you're just a click away from remote power On, Off or Reboot!

RedHat
Approved for Red Hat Cluster Suite

Easy to Configure, Easy to Use

The NPS-8H20-ATS-2 can be configured via SSH or SNMP, or locally via the serial console port. Easy to master, user-friendly menus and commands allow you assign a location name, set system parameters and view plug status. Outlets can be switched on, off, rebooted or set to user-defined default status using plug numbers or names.

Versatile Alarm Functions for Automatic Reboot and Power Switching

In addition to performing on-demand reboots and power switching, the NPS-8H20-ATS-2 also includes an assortment of administrator-defined alarm features, which can be used to automatically reboot or switch outlets when high rack temperatures, open circuit breakers, power supply irregularities, unresponsive network elements and other important events and factors are detected. When any of these alarm functions are triggered, the NPS-8HD20-2 can also provide notification via email, SNMP trap or SYSLOG message. Each alarm includes a configuration menu that can be used to customize alarm triggers and response actions to fit the requirements of your specific application.

Security and Co-Location

Access to the NPS-8H20-ATS-2 command mode is password protected to prevent unauthorized users from invoking sensitive switching and configuration functions. Both the Web Browser Interface and Command Line Interface require the user to enter a password and username before allowing access.

The NPS-8H20-ATS-2 also features four different levels of user accounts; Administrator Level, Super User Level, User Level and View Only Level. Administrators are allowed access to all configuration and operational commands. Super Users are allowed to direct switching commands to any outlet and can view configuration menus, but are not allowed to change configuration parameters. User accounts are allowed to invoke switching commands, but are limited to the switched outlets that are specifically defined for the user account. View Only level accounts are allowed to display NPS status screens, but are not allowed to invoke switching commands or configuration commands.

Reliability and Support

TheNPS-8H20-ATS-2 is built in the USA and backed by a five year warranty. WTI products are installed in thousands of network sites worldwide. Our customers know they can depend on WTI for superior quality and reliability for their most mission-critical operations.


Includes Enterprise Management Software

console server with enterprise management software

All WTI console server and switched PDU products include WTI’s convenient Enterprise Management Software, which drastically simplifies the task of managing multiple WTI devices spread throughout your network infrastructure. The WMU Enterprise Management Software provides a centralized command interface that allows administrators to easily manage, label and control multiple WTI console servers and switched PDUs in large network applications, reducing the time required to access console port command and power control and reboot functions for connected devices.

Once installed on your PC or laptop, the WMU Enterprise Management Software can search a user-defined IP address range on your network and discover all WTI console servers and switched PDUs within the range. Discovered units are then added to the Enterprise Management Software’s inventory, allowing administrators to assign a descriptive tag to each WTI device in order to denote the location or function of the device. In addition to providing a centralized interface for remote console port access and power reboot and control functions, the Enterprise Management Software can also be used to control firmware updates for WTI products and edit and manage user accounts at individual or multiple WTI devices.



Power Control & Management:

  • Remote Individual or Group Outlet Switching
  • Asynchronous Power Transfer Switching for Automatic Power Redundancy (Primary - Secondary)
  • On, Off, Reboot, Default, or Load Shed Switching
  • Outlet Sequencing & Power Up Delays
  • User-Defined Power-Up Default Status & Outlet Status Retention
  • Plug Naming, Grouping & Access Control
  • Scheduled On, Off, Reboot Switching
  • Ping Watchdog with Auto Reboot
  • IP & SNMP Control

Metering, Monitoring, Reporting:

  • Reports Temperature
  • Over-Temperature Alarms
  • Lost Voltage (Line In) Alarm
  • Ping-No-Answer Alarm
  • Invalid Access Lockout Alarm
  • Circuit Breaker Open Alarm
  • Power Cycle Alarm
  • No Dialtone Alarm
  • Alarm Notification via Email, SNMP, SYSLOG
  • Alarm, Command, Access Audit, Temperature Logging

Access/Security/Authentication:

  • In-Band (10/100Base-T Ethernet Port)
  • Supports Both IPv4 and IPv6
  • Out-of-Band (External Modem Ready)
  • Local (RJ45 RS232 SetUp Port)
  • SSHv2 Encryption
  • Embedded Validated FIPS 140-2 Cryptographic Module
  • HTTPS/SSL/TLS Secure Web
  • Multi-Level Subscriber Directory with Outlet-Specific Password Protection
  • IP Address Filtering
  • Remote Authentication: LDAP/Kerberos/RADIUS/TACACS+
  • PPP

Network-grade Power Distribution:

  • (2) 20 Amp In-Feeds
  • 1U Horizontal Mounting
  • 19" Rack Mounting Brackets

Unit Management:

  • Compatible with SNMP-based Enterprise Management Utilities
  • Includes WMU Enterprise Management Software
  • CLI plus Web-based GUI
  • SNMP Control, Monitoring, and Configuration with Full MIB Support (Supports SNMP Versions 1, 2C and 3)
  • Multiple Concurrent SSH Sessions
  • SSL Web Browser

Green Features:

  • Scheduled On/Off/Reboot Power Switching
  • Controlled via Cisco EnergyWise

Specifications

Interface Descriptions:
Ethernet Port: 10/100Base-T, RJ45
Console Port: (1) RJ45, RS232C
Power:
Voltage: 200 - 250 VAC, 50/60 Hz
Power Distribution:
(80% Derated)
3.2/4 kW
Power Outlets: (8) IEC-60320-C13
Power Inlets: (2) IEC-60320-C20
Input Feeds: (2) 20 Amps (Primary - Secondary ATS)
Current: Primary 20 Amps (16A Derated) or Secondary 20 Amps (16A Derated)
Power Input Cables: Detachable, Sold Separately
Physical/Environmental:
Size: 1.75"H x 19"W x 8.7"D (1U)
(4.5 cm H x 48.3 cm W x 22.1 cm D)
Weight: 12 Lbs. (5.4 Kg) Shipping Weight
Operating Temperature: 32° to 122° F (0° C to 50° C)
Humidity: 10% to 90% RH
Mounting: 19" Rack Brackets Included
Agency Approvals:
FCC, UL, CE

Power Cables (Order Separately)

Part # Supply Plug Equipment End Rating Description
DPC-19-620P-8F NEMA 6-20P C19 20A/250V NEMA 6-20P to IEC-60320-C19
8FT (2.4M)
DPC-19-L620P-8F NEMA L6-20P C19 20A/250V NEMA L6-20P to IEC-60320-C19
8FT (2.4M)

DEC-19-20-6F
DEC-19-20-8F
DEC-19-20-10F
C20 C19 20A/250V IEC-60320-C20 to IEC-60320-C19
6FT (1.8M)
8FT (2.4M)
10FT (3.05M)

When new, improved versions of product firmware become available, the "Upgrade Firmware" function can be used to update the unit. To receive the latest available firmware update from WTI Technical Support, please click on the link below and complete the form.

Request Firmware

To speak with a qualified sales engineer about your firmware request, please call: 1.800.854.7226



Latest Firmware Version:

Any questions? Submit your request regarding this product.