4. Configuration


When the NLJ-512 is shipped from the factory, options and parameters are set to fit the requirements of most call accounting applications.  In many cases, if you do not choose to include the NLJ’s advanced features, no further configuration is required.

However, if you do intend to use advanced features (such as the Data Filter or Alarm Filter), or if your application requires parameters other than the defaults described in this section, the unit must be properly configured.  This section describes how to reconfigure the NLJ-512 to meet the requirements of almost any data collection application.

Although the NLJ provides a substantial assortment of advanced program features, it is not necessary to include all of these features in your system configuration.  You may wish to complete the basic set-up first, and then add optional features as needed.

When configuring the unit, note that the Status Screens can be accessed via item 1 in the Main Menu.  This allows you to determine the current state of any feature, and verify that parameters are correctly defined. For more information on the Status Screens, please refer to Section 6.



4.1. Access to the Command Mode


When the command mode is active, the unit will display a series of menus used to select parameters, enable options, and retrieve stored data.

During initial configuration, command mode can only be accessed via the Console Port or Modem Port.  After network parameters have been defined, you will also be able to access the Command Mode via the Network Port.

PollCat NetLink Jr. Main Menu	Supervisor Mode

FUNCTIONS: 			CONFIGURATION

1. Status Displays 		21. Default Parameters
2. Buffer Functions 		22. Port Congfiguration
3. System Functions 		23. System Parameters
4. System Diagnostics 		24. Scheduled Action Parameters
5. ^Bxx Command Help 		25. Alarm Configuration
6. Recall Parameters 		26. Data Filter Configuration
7. Save Parameters              27. FTP Push Configuration
8. Exit Command Mode            28. FTP Server Configuration

Enter Selection ...

Figure 4.1:  Main Menu



To access the Command Mode for initial configuration, proceed as follows:

  1. Local Access:  To communicate via the Console Port, start your communications program (e.g. ProComm).

    1. If Set-Up Switch 7 is UP (enable Console Port Password), the system will send the "PollCat-NetLink" (Password) Prompt.

    2. Key in the password (case-sensitive), press [Enter]. The Default Supervisor Password is SUPER.

  2. Access Via Modem:  Start your communications program (e.g. ProComm) and dial the line connected to the NLJ.

    1. The unit will send the "PollCat-NetLink" (Password) prompt after the carrier is detected.

    2. Key in the password (case-sensitive), press [Enter]. The Default Supervisor Password is SUPER.

  3. Access via Network:  During initial configuration, the NLJ cannot be accessed via Network, because parameters such as the IP address and gateway mask have not been defined yet. After network parameters have been defined (see Section 4.4.4), a Telnet session can be established using the following format:

    telnet ipaddress port [Enter]

    Where:

    ipaddress   The NLJ-512's IP Address
    port (Optional) The desired Port Number. If omitted,
    telnet will connect to port #23 by default; Command
    Echo will be set according to the NLJ-512's current configuration,
    and $FF Stuffing will be enabled. Options:
    2001    Behaves same as port #23.
    3001 Preconfigured with Echo enabled,
    and $FF Stuffing Off.

    Notes:

    • The NLJ-512 will allow 3 attempts to enter a valid password.  If a valid password is not entered in 3 attempts, the NLJ will disconnect.


    • If an invalid password is entered, the NLJ will respond with the ERROR message.

After a brief pause, the NLJ Main Menu will appear as shown in Figure 4.1.



4.2. Menu System Conventions


  1. Access to Submenus: All menus are key activated. To access a menu, key in the number for the desired item and then press [Enter].

  2. User Level / Supervisor Level Functions: Note that most configuration menus are not available in User Mode. In order to perform the setup procedures described in this section, the NLJ-512 must be operating in Supervisor Mode. The top of the Main Menu indicates whether the User Mode or Supervisor Mode is currently selected.

    To switch from User Mode to Supervisor Mode, select Main Menu Item 3 "System Functions". When the System Functions menu appears, select item 1 "Security Level", and then select Supervisor. Key in the Supervisor password (Default = SUPER) and press [Enter].

    For more information on User functions and Supervisor functions, please refer to Appendix D.

  3. Save Parameters: After configuring the NLJ-512, it is recommended to save parameters to flash memory. If parameters are not saved, the NLJ will revert to the previous configuration when power to the unit is switched off or interrupted. To save parameters to flash memory, go to the Main Menu, type 7 and press [Enter]. For more information, please refer to Section 13.



4.2.1. Script Access to Menu Functions

NLJ-512 menu functions can also be accessed using scripts. This allows you to create polling programs that select items from command menus in order to change parameters. When writing polling software, use the following conventions:

  1. Wait for Menu: To allow the polling program to determine when a menu has been completely sent, search for the character(s) at the end of the menu. For most menus, the last three characters will be an ellipsis (three periods).


  2. Selecting Menu Items: Specify the desired menu item by number, followed by a carriage return.


  3. Moving Up One Level: To exit from a menu and return to the previous menu, send an Escape character.



SYSTEM PARAMETERS:

1. Supervisor Password: 	(...)
2. User Password 1: 		SMDR
3. User Password 2: 		(undefined)
4. Site ID Msg: 		(undefined)
5. Wrap-Around: 		Off
6. Real-Time Clock: 		05/08/2001 Tue 15:06:51

Enter Selection,
Press <ESC> to return to previous menu ... 

Figure 4.2:  System Parameters Menu


4.3. Set System Parameters


The System Parameters menu (Figure 4.2) is used to set common parameters, such as Command Mode Passwords and the Site ID Message.  To access the System Parameters menu, go to the Main Menu, type 23 and press [Enter].  The following items can be configured via this menu:

  1. Supervisor Password:  Defines the Supervisor password.  When this password is entered at the Password Prompt, the NLJ-512 will start up in Supervisor Mode, allowing access to all menu and command functions. (Default = SUPER).

  2. User Password 1:  Defines the first User Password. When this password is entered at the Password prompt, the NLJ will start up in User Mode, allowing limited access to menu and command functions. (Default = SMDR).

  3. User Password 2:  Defines the second User Password. When entered at the Password prompt, the NLJ-512 will start up in User Mode, allowing limited access to menu and command functions. (Default = undefined).

  4. Site ID Message:  Defines a text string (up to 32 char.) that identifies the location where the unit is installed.  If this item is defined, the Site ID will be displayed prior to the Command Prompt, each time the command mode is accessed. The Site ID can also be displayed via the System Status Screens (Main Menu, Item 1). (Default = undefined).

    Notes:

    • If the Site ID message begins with an underscore (_), the message will be displayed after the command prompt. The underscore character will not appear when the Site ID is displayed.
    • If the Console Port Password is disabled (Sw7=Down), the Site ID message will not be displayed when the unit is contacted via the Console Port.

PORT CONFIGURATION:

1. PBX Port A
2. ---
3. ---
4. Console Port
5. Modem Port
6. Network Port

Enter Selection,

Press <ESC> to return to previous menu ...

Figure 4.3:  Port Selector Menu


  1. Wrap-Around:  If internal memory becomes full, the wrap-around option allows new data to be written over older data.  This enables the unit to continually recycle its memory. While Command Mode is active, new data will not overwrite older data in the current partition.  Any new data will be stored outside the top boundary.  If memory is full, no additional data will be stored while Command Mode is active. (Default = On).

    Note: When Wrap-Around is enabled and memory becomes full, there will be a noticeable delay while the unit clears old data and writes new data to flash memory. During this period, the NLJ will delay response to additional commands until the wrap-around process is complete. Note that newly received data will not be lost during this delay.

  2. Real-Time Clock:  Sets the NLJ’s internal clock and calendar.  Since time dependent features (e.g. Scheduled Actions, PBX Inactivity Alarm) rely on the internal clock, it is important that the clock and calendar are accurately set.



4.4. Port Configuration


To configure the PBX Input Port, Console Port, Modem Port or Network Port, go to the Main Menu, type 22 and press [Enter].  The Port Selector Menu (Figure 4.3), will be displayed.  To select and configure ports, proceed as follows.



4.4.1. PBX Input Port (PBX Port A)

From the Port Selector Menu, type 1 and then press [Enter]. The configuration menu includes the following items:


PBX PORT A:

COMMUNICATION SETTINGS 			INPUT PARAMETERS
1. Baud Rate: 		9600 		11. Time/Date Stmp: 	Off
2. Bits/Parity: 	7-Even 		12. Serial No Stmp: 	Off
3. Stop Bits: 		1 		13. Strip Non-Prnt: 	On
4. Handshake Mode: 	None 		14. End Character: 	^J
					15. Alarm Filter: 	Off
					16. Store Alm Data: 	Alarm
					17. Data Filter: 	Off
					18. PBX Inact Alm: 	Off

Enter Selection,
Press <ESC> to return to previous menu ... 

Figure 4.4:  PBX Port Configuration Menu


Communication Settings:

  1. Baud Rate:  Selects the baud rate for this port. Any standard rate from 1200 bps to 115.2K bps. (Default values are selected by Set-Up Switches 4 and 5).

  2. Bits/Parity:  Selects Bits/Parity for this port; 8-None, 7-Even,
    7-Odd, or 7-None. (Default = 7-Even).

  3. Stop Bits:  Selects stop bits for this port. (Default = 1).

  4. Handshake Mode:  Selects flow control for this port; XON/XOFF, RTS/CTS, both, or None. (Default = None).



Input Parameters:

  1. Time/Date Stamp: The date stamp can be inserted at the beginning of each record received by this port. This prompt is used to disable the function, or select the short format or long format. The short format (PollCat III Compatible) lists Month, Date, Hour and Minute; the long format lists Month, Date, Year, Hour, Minute, and Second. (Default = Off).

  2. Serial Number Stamp:  Inserts a six digit number at the beginning of records received by this port.  (Default = Off).

  3. Strip Non-Printables:  Conserves memory by excluding characters such as Nuls and Dels. (Default = On).

  4. End Character:  Defines the End-of-Record (EOR) character that the NLJ expects to see at the end of each record received at this port.  (Default = ^J (Line Feed)).

  5. Alarm Filter:  Enables/disables the Alarm Filter and selects the Alarm Filter Format for this port.  The Alarm Filter monitors data, and notifies the user when specific types of data are detected. For more information, please refer to Section 8. (Default = Off).

  6. Store Alarm Data: Determines where the NLJ will store alarm data received via this port. Alarm Records can be stored in the Alarm File, the Standard (non-alarm) File, or both files. For more information on files, please refer to Section 14.1.1. (Default = Alarm)

  7. Data Filter:  Enables/disables the Data Filter and selects the Data Filter Format used by this port.  The Data Filter conserves memory and cuts polling time by excluding records not needed for your application.  For more information, please refer to Section 7. (Default = Off).

  8. PBX Inactivity Alarm:  Enables/disables the PBX Inactivity Alarm and selects the format for this port.  The inactivity alarm monitors the flow of data from the PBX and notifies the user if the flow stops.  For further instructions, please refer to Section 9. (Default = Off).



4.4.2. Console Port Configuration

The Console Port is used for connection to a local control device, such as a PC or terminal.  To configure the Console Port, first go to the Port Selector Menu (Main Menu, item 22).  Type 4 and press [Enter].  The Console Port Configuration Menu (Figure 4.5) will be displayed.  The following options are available:

Communication Settings:

  1. Baud Rate:  Selects the baud rate for this port; any standard rate from 1200 bps to 115.2K bps. (Default value is selected by Set-Up Switches 1, 2, and 3).

  2. Bits/Parity:  Selects Bits/Parity for this port; 8-None,
    7-Even, 7-Odd, or 7-None. (Default = 8-None).

  3. Stop Bits:  Selects stop bits for this port. (Default = 1).

  4. Handshake Mode:  Selects the flow control mode for this port; XON/XOFF (Software), RTS/CTS (Hardware), both, or None. (Default = RTS/CTS).



General Parameters:

  1. Command Echo:  Enables / Disables the command echo for this port. During set-up, it may be helpful to enable the Command Echo.  This allows keystrokes sent to the NLJ to be displayed on your monitor. (Default = On).

CONSOLE PORT:

COMMUNICATION SETTINGS 			OUTPUT PARAMETERS
1. Baud Rate: 		9600 		21. Output Mode: 	ASCII Record
2. Bits/Parity: 	8-None 		22. Data on ^B01: 	On
3. Stop Bits: 		1 		23. Hold End Data: 	On
4. Handshake Mode: 	RTS/CTS 	24. Line # Tag: 	Off
 					25. Send Compress: 	Off
 					26. Auto Delete: 	Off



 					OUTPUT PARAMETERS (BINARY BLOCK)
				 	27. Transmit Att: 	3
 					28. Transmit Delay: 	5 Sec
 					29. DLE Stuffing: 	Off
GENERAL PARAMETERS
11. Command Echo: 	On
12. Response Type: 	Inhibit Menu
13. "Sure" Prompt: 	On
14. CMD Timeout: 	15 Min
15. Audit Trail: 	Off

ACTION PARAMETERS
16. Action Delay: 	10 Sec

Enter Selection, Press <ESC> to return to previous menu ... 

Figure 4.5:  Console Port Configuration Menu


  1. Response Type:  Determines how the port will react when command mode is activated. If "Display Menu" is selected, the Main Menu will be displayed immediately whenever command mode is activated. If "Inhibit Menu" is selected, the NLJ will not display the Main Menu until [Enter] is pressed. (Default = Inhibit Menu).

  2. "Sure" Prompt:  When irreversible commands (such as "Erase Data") are invoked at this port, the NLJ can display the "Sure" prompt to allow one last chance to verify that the command should be executed. (Default = On).

  3. Command Timeout:  Sets the Timeout value for this port.  When the NLJ detects no command activity at this port for the specified timeout period, the port will exit command mode and disconnect. (Default =15 minutes).

  4. Audit Trail: Enables or Disables the Audit Trail function. When enabled, the NLJ will log command activity at this port. To review the command activity log, please refer to Section 15.1.7. (Default = Off).



Action Parameters:

  1. Action Delay: When multiple alarm actions are directed to this port, the action delay determines how much time will elapse between actions. The Action Delay makes it easier to connect to the port, by providing a window when the port is not busy sending out actions. (Zero to 9999 Seconds; Default = 10 sec).



Output Parameters:

  1. Output Mode:  Selects the data output format for this port; ASCII Record, Binary Block, Xmodem, or Zmodem.  
    (Default = ASCII Record)
    .

    Note: When using Zmodem Output Mode, please refer to the cautions listed in Section 14.7.

  2. Data on ^B01:  If enabled, the NLJ will immediately begin sending data when the data release command is invoked (Menu or ^B01). If disabled, the NLJ will send the "READY" message, then wait for Command ^B02 before releasing data. (Default = On).

  3. Hold "End Data":  At the end of each data release session, the NLJ will send the "End Data" message before returning to command mode.  When this option is enabled, this port will wait for Command ^B02 before sending the End Data message.
    (Default = On).

  4. Line # Tag:  Inserts a Line Number at the beginning of each record or block released by this port.  These Line Numbers are not stored in internal memory, but are added when data is released.  
    (Default = Off)
    .

  5. Send Compressed:  Determines whether this port will release data in space compressed or normal format.   (Default = Off).

  6. Auto Delete:  When enabled, data will be automatically deleted from the NLJ's memory at the end of each successful read. If the read operation is interrupted, data will not be deleted.
    (Default = Off).

    Note: Before enabling the Auto Delete function, please refer to the notes and cautions listed in Section 14.6.

Output Parameters (Binary Block Mode Only):

  1. Transmit Attempts:  (Binary Mode Only) Determines how many times this port will resend a block when there is a transmission problem, or the connection is lost. (Zero to 99 attempts;
    Default = 3
    ).

  2. Transmit Delay:  (Binary Mode Only) Determines how long this port will wait between transmit attempts. If this value is set to Zero, binary data will be sent in a continuous block, without acknowledgment. (Zero to 99 seconds; Default = 5 seconds).

  3. DLE Stuffing:  (Binary Mode Only) Allows literal characters to be inserted into binary data released by this port. (Default = Off).



MODEM PORT: 		Modem Installed

COMMUNICATION SETTINGS 			 OUTPUT PARAMETERS
1. Baud Rate: 		57600 		 21. Output Mode: 	ASCII Record
2. Bits/Parity: 	8-None 		 22. Data on ^B01: 	On
3. Stop Bits: 		1 		 23. Hold End Data: 	On
4. Handshake Mode: 	RTS/CTS 	 24. Line # Tag: 	Off
5. Reset String: 	ATZ 		 25. Send Compress: 	Off
6. Init String: 	ATE0M0Q1&C1&D2S0 26. Auto Delete: 	Off
  (Cont.): 		=1 
7. Hang-Up String: 	(undefined) 	 OUTPUT PARAMETERS (BINARY BLOCK) 
  (Cont.): 				 27. Transmit Att: 	3 
8. Reset Modem 				 28. Transmit Delay: 	5 Sec 
					 29. DLE Stuffing: 	Off 
GENERAL PARAMETERS
11. Command Echo: 	On 		 CALLOUT PARAMETERS
12. Response Type: 	Inhibit Menu 	 31. Dial Attempts: 	3
13. "Sure" Prompt: 	On 		 32. Sequence Att: 	3
14. CMD Timeout: 	15 Min 		 33. Sequence Delay: 	10 Min
15. Audit Trail: 	Off 		 34. Imm Callout: 	Off
					 35. Imm Phone #: 	(undefined)
ACTION PARAMETERS 			     (Cont.):
16. Action Delay: 	300 Sec 	 36. Dialback Scrty: 	Off

Enter Selection, Press <ESC> to return to previous menu ... 


Figure 4.6:  Modem Port Configuration Menu


4.4.3. Modem Port Configuration

To configure the Modem Port, go to the Port Selector Menu (Main Menu, item 22), and select item 5 to display the Modem Port Configuration Menu.  The following options are available:

Communication Settings:

  1. Baud Rate:  Selects the baud rate for this port; any standard rate from 1200 to 115.2K bps. (Default = 57600).

  2. Bits/Parity:  Selects Bits/Parity for this port; 8-None, 7-Even, 7-Odd, or 7-None. (Default = 8-None).

  3. Stop Bits:  Selects stop bits for this port. (Default = 1).

  4. Handshake Mode:  Selects the flow control mode for this port; XON/XOFF (Software), RTS/CTS (Hardware), both, or None. (Default = RTS/CTS).

  5. Reset String:  Defines the modem reset message. (Up to 16 characters; Default = ATZ).

  6. Initialize String:  Defines the modem initialization string. (Up to 32 characters; Default = ATE0M0Q1&C1&D2S0=1).

  7. Hang-Up String:  Defines the modem hang-up string. (Up to 32 characters; Default = undefined).

  8. Reset Modem: Resets the internal modem.



General Parameters:

  1. Command Echo:  Enables / disables command echo for this port. During set-up, it may be helpful to enable command echo.  This allows keystrokes sent to the NLJ to be echoed back and displayed by your communications program. (Default = On).

  2. Response Type:  Determines how this port will react when command mode is activated. If "Display Menu" is selected, the NLJ will immediately display the Main Menu when command mode is activated. If "Inhibit Menu" is selected, the NLJ will not display the menu until [Enter] is pressed. (Default = Inhibit Menu).

  3. "Sure" Prompt:  When irreversible commands are invoked at this port, the NLJ can display a "Sure" prompt to allow one last chance to verify that the command should be executed. (Default = On).

  4. Command Timeout:  When no additional command activity is detected at this port during the specified timeout period, the port will exit command mode and disconnect. (Default =15 minutes).

  5. Audit Trail: Enables or Disables the Audit Trail function. When enabled, the NLJ will log command activity at this port. To review the activity log, please refer to Section 15.1.7. (Default = Off).



Action Parameters:

  1. Action Delay: When multiple alarm actions are directed to this port, the action delay determines how much time will elapse between actions. This makes it easier to connect, by providing a window when the port is not busy sending out actions. (Zero to 9999 Seconds; Default = 300 Seconds).



Output Parameters:

  1. Output Mode:  The output format for the port; ASCII Record, Binary Block, Xmodem or Zmodem.  (Default = ASCII Record).

    Note: When using Zmodem Output Mode, please refer to the cautions listed in Section 14.7.

  2. Data on ^B01:  When enabled, the NLJ will immediately begin sending data if the data release command is invoked. When disabled, the NLJ will send the "READY" message, then wait for a ^B02 before releasing data. (Default = On).

  3. Hold "End Data":  At the end of each data release session, the NLJ will send the "End Data" message before returning to command mode.  When this option is enabled, this port will wait for a ^B02 before sending the End Data message. (Default = On).

  4. Line # Tag:  Inserts a Line Number at the beginning of each record or block released by this port.  Line Numbers are not stored in memory, and are added when data is released.  (Default = Off).

  5. Send Compressed:  Determines whether this port will release data in space compressed or normal format.  (Default = Off).

  6. Auto Delete:  When enabled, data will be automatically deleted from NLJ memory at the end of each successful read. If the read is interrupted, data will not be deleted. (Default = Off).

    Note: Before enabling the Auto Delete function, please refer to the notes and cautions listed in Section 14.7.



Output Parameters (Binary Block Mode Only):

  1. Transmit Attempts:  (Binary Mode Only) The number of times this port will attempt to resend a block when there is a transmission problem, or the connection is lost. (Zero to 99 attempts; Default = 3).

  2. Transmit Delay:  (Binary Mode Only) The length of time this port will wait between transmit attempts. Note that if this value is Zero, binary data will be sent in a continuous block, without acknowledgment. (Zero to 99 seconds; Default = 5 seconds).

  3. DLE Stuffing:  (Binary Mode Only) Allows literal characters to be inserted into binary data released by this port. (Default = Off).



Callout Parameters:

  1. Dial Attempts:  The number of times the modem will redial the Callout Number when there is no answer, or the carrier is not received.  (Zero to 99 attempts; Default = 3).

  2. Sequence Attempts:  The number of times the modem will restart the callout routine if the defined number of dial attempts is performed and there is no answer, or the carrier is not received.  (Zero to 99 attempts; Default = 3).

  3. Sequence Delay: The amount of time between sequence attempts. (Zero to 999 minutes; Default = 10 min.).

  4. Immediate Callout:  Activates the Immediate Callout feature.  When enabled, the NLJ will dial the Immediate Phone Number after the user disconnects.  Note that this feature must be enabled prior to each use, and the Immediate Phone Number must be defined in order for this feature to function. (Default = Off)

  5. Immediate Phone #:  The number that is dialed when an Immediate Callout is performed. (Up to 32 characters; Default = undefined).

  6. Dialback Security:  Defines and enables dialback security parameters. For more information, please refer to Section 4.4.3.1. (Default = Off).



DIALBACK SECURITY

1. Dialback Security:  		Off
2. Supervisor Dialback Phone #: (undefined)
3. User Dialback Phone #1:  	(undefined)
4. User Dialback Phone #2:  	(undefined)

Enter Selection,
Press <ESC> to return to previous menu ...

Figure 4.7:  Dialback Security Configuration Screen


4.4.3.1. Dialback Security

This feature provides an extra measure of security for modem access to command mode. When this option is configured and enabled, the NLJ will dial a user-defined number before allowing access to command mode.

If Dialback Security is active, the NLJ will display the Password prompt when a user contacts the unit via modem. If the caller enters a valid password, the NLJ will then disconnect and call the user-defined number for that password. After successfully contacting the dialback number, the NLJ will again display the password prompt. If a valid password is entered by the answering party, the NLJ will then allow access to command mode.

The Dialback Security feature will recognize up to three passwords; one Supervisor Password and two User Passwords. The Supervisor password allows access to all configuration menus. The User passwords will not allow access to configuration menus.

To access the Dialback Security menu from the Modem Port Configuration menu, type 36 and press [Enter]. The Dialback Security menu (Figure 4.7) offers the following options:

  1. Dialback Security: Enables/disables the Dialback Security feature. (Default = Off).

  2. Supervisor Dialback Phone #: The dialback number that will be used when a caller enters the valid Supervisor Password. (Up to 32 characters; Default = undefined).

  3. User Dialback Phone # 1: The dialback number that will be used when a caller enters the User 1 Password. (Up to 32 characters; Default = undefined).

  4. User Dialback Phone # 2: The dialback number that will be used when a caller enters the User 2 Password. (Up to 32 characters; Default = undefined).



Network PORT:		NIC Installed

COMMUNICATION SETTINGS 			OUTPUT PARAMETERS
1. IP Address: 		(undefined) 	21. Output Mode: 	ASCII Record
2. Subnet Mask: 	255.255.255.0 	22. Data on ^B01: 	On
3. Gateway Addr: 	(undefined) 	23. Hold End Data: 	On
4. SNMP Manager 1: 	(undefined) 	24. Line # Tag: 	Off
5. SNMP Manager 2:	(undefined)	25. Send Compress: 	Off
6. SNMP Community:	public		26. Auto Delete: 	On
7. Reset Network
8. Send MSS:		1460		OUTPUT PARAMETERS (BINARY BLOCK)
					27. Transmit Att: 	3
					28. Transmit Delay: 	5 Sec
					29. DLE Stuffing: 	Off
GENERAL PARAMETERS
11. Command Echo: 	On
12. Response Type: 	Inhibit Menu
13. "Sure" Prompt: 	On
14. CMD Timeout: 	60 Min
15. Audit Trail: 	On

ACTION PARAMETERS
16. Action Delay: 	10 Sec

Enter Selection, Press <ESC> to return to previous menu ... 


Figure 4.8:  Network Configuration Menu


4.4.4. Network Configuration

Settings for network parameters, such as the IP Address and Subnet Mask, will be determined by your network configuration.  Please contact your network administrator for appropriate settings, then assign parameters as described in this section.

To configure the Network Port, go to the Port Selector Menu (Main Menu, item 22), and select item 6. The Network Port Configuration Menu (Figure 4.8) offers the following options:

Communication Settings:

  1. IP Address:  The NLJ's IP Address (Default = undefined).

  2. Subnet Mask:  Defines the NLJ's subnet mask. (Default = 255.255.255.0).

  3. Gateway Address:  Defines the NLJ's Gateway Address.
    (Default = undefined).

  4. SNMP Manager 1:  Defines the IP Address for the first SNMP Manager. The NLJ allows definition of two SNMP Managers. (Default = undefined).

  5. SNMP Manager 2:  The IP Address for the second SNMP Manager. (Default = undefined).

  6. SNMP Community:  Defines the SNMP Community. (Default = public).

  7. Reset Network:  Reinitializes the network port.

  8. Send MSS: Sets the Maximum Segment Size for TCP/IP packets sent by the NLJ. (Default = 1460.)



General Parameters

  1. Command Echo:  Enables / Disables the command echo for this port. During set-up, it may be helpful to enable Command Echo.  This allows keystrokes sent to the NLJ to be echoed back and displayed on your monitor.  (Default = On).

  2. Response Type:  Determines how this port will react when the Command Mode is activated. If "Display Menu" is selected, the NLJ will immediately display the Main Menu when the Command Mode is activated. If "Inhibit Menu" is selected, the NLJ will not display the Main Menu until [Enter] is pressed. (Default = Inhibit Menu)

  3. "Sure" Prompt:  When irreversible commands (such as "Erase Data") are invoked, this port can display the "Sure" prompt to allow one last chance to verify that the command should be executed. (Default = On).

  4. Command Timeout:  Sets the Timeout value.  If no additional command activity is detected at this port during the defined timeout period, this port will exit Command Mode and disconnect. (Default =15 minutes).

  5. Audit Trail: Enables or Disables the Audit Trail function. When enabled, the NLJ will log command activity at this port. To review the command activity log, please refer to Section 15.1.7. (Default = Off).



Action Parameters:

  1. Action Delay: When multiple alarm actions are directed to this port, the action delay determines how much time will elapse between actions. This makes it easier to connect to the port, by providing a window when the port is not busy sending out actions. (Zero to 9999 Seconds; Default = 10 Seconds).



Output Parameters:

  1. Output Mode:  Selects the data output format for this port; ASCII Record, Binary Block, Xmodem or Zmodem.
    (Default = ASCII Record)
    .

    Note: When using Zmodem Output Mode, please refer to the cautions listed in Section 14.7.

  2. Data on ^B01:  When enabled, the NLJ will immediately begin sending data when the data release command is invoked (Menu or ^B01). When disabled, the NLJ will send the "READY" message, then wait for Command ^B02 before releasing data. (Default = On).

  3. Hold End Data:  At the end of each data release session, the NLJ will send the "End Data" message before returning to Command Mode.  When "Hold End Data" is enabled, this port will wait for Command ^B02 before sending the End Data message. (Default = On).

  4. Line # Tag:  Inserts a Line Number at the beginning of each record or block released by this port.  These Line Numbers are not stored in the NLJ’s internal memory, but are added when data is released.  (Default = Off).

  5. Send Compressed:  Determines whether this port will release data in space compressed or normal format. (Default = Off).

  6. Auto Delete:   When enabled, data will be automatically deleted from the NLJ's memory at the end of each successful read. If the read is interrupted, data will not be deleted. (Default = Off).

    Note: Before enabling the Auto Delete function, please refer to the notes and cautions listed in Section 14.6.



Output Parameters (Binary Block Mode Only):

  1. Transmit Attempts:  (Binary Mode Only) Determines how many times this port will resend a block after a transmission interruption, or lost connection. (Zero to 99 attempts; Default = 3).

  2. Transmit Delay:  (Binary Mode Only) Determines how long this port will wait between transmit attempts. If this value is set to Zero, binary data will be sent in a continuous block, without acknowledgment. (Zero to 99 seconds; Default = 5 seconds).

  3. DLE Stuffing:  (Binary Mode Only) Allows literal characters to be inserted into binary data released by this port. (Default = Off).