MPC-8H-1 Rack Mount PDU, Switched, 1U, Dual 20A, 120V, (8)5-20R

WTI Switched Rack Mount PDU , 1U Mounting , 120V AC Output , (8)NEMA 5-20R Receptacles
Price: $895.00
MPC-8H-1 Rack Mount PDU, Switched, 1U, Dual 20A, 120V, (8)5-20R

Dual Input
Voltage: 120V
Current: (2) 20A (16A Derated)
Connector: (2) IEC C20 for Detachable Power Cables

Dual Output
Voltage: 120V
Current: (2) 20A (16A Derated)
Outlets: (8) NEMA 5-20R
Overcurrent Protection: (2) 20A Circuit Breakers

WTI rack mount switched PDUs enable complete control over current, power and energy usage within your data center and across the network. As the first and only rack mount PDUs to meter, report and control total current, power and energy consumption, our switched power distribution units are the perfect solution for data centers striving for LEED certification or reducing energy costs. WTI rack mount switched PDUs can meter and report kWh, kW, A, V, Temperature and schedule equipment shutdowns based on user defined threshold alarms or when devices need a simple power reboot. Energy, power and current data from IT equipment is measured on each circuit within your data center or network and used for billing, heat calculation and load distribution.

WTI rack mount switched PDUs can be used with its standalone IP web browser interface or any MIB based SNMP enterprise management software. To see a complete list of approved software or to recommend software for compatibility testing, please see our Software Integration section.

Current Power & Energy Management:

  • Meter & Report Kilowatt-Hours in the Data Center
  • Meter & Report Amperage Loads on Each Circuit
  • Meter & Report Kilowatts for Cooling Demands
  • Meter & Report Voltage Input
  • Sense & Report Temperature
  • Graph Daily, Weekly, Monthly & Yearly Power Consumption
  • Power Load-Shedding w/ Auto Recovery

Access/Security/Control:

  • 10/100Base-T Ethernet Port
  • SNMP Control (v1,v2c,v3)
  • SSHv2 Encryption
  • LDAP, Kerberos, RADIUS, TACACS+
  • Alarm Notification via Email, SNMP, Syslog, text message, LED or audible alarm
  • Command Logging with Audit Trail
  • SSL Web Browser (Https) for Set Up and Operation
  • Approved Software Integration

Data Center Power Metering:

  • True RMS Current Metering
  • Local 3 Digit LED Display
  • Current Load Data Collection/Aux Unit Polling
  • Amp Metering On Each In-Feed
  • User Defined Threshold Alarms

Remote Reboot & Power Switching:

  • IP & SNMP Control
  • Remote Outlet Switching
  • Automatically Power Reboot Locked Equipment
  • Timed & Scheduled Power Reboot/Shutdowns

Network-grade Power Distribution:

  • Circuit Breaker Protection
  • Dual 20 Amp In-Feeds
  • 1U Horizontal Mounting
  • 19" Rack Mounting Brackets

Avocent® DSView®
Certified
Nagios®
Certified

Power Cables (Order Separately)

Part # Supply Plug Equipment End Rating Description
DPC-19-520P-8F NEMA 5-20P C19 20A/125V NEMA 5-20P to IEC-60320-C19
8FT (2.4M)
DPC-19-L520P-8F NEMA L5-20P C19 20A/125V NEMA L5-20P to IEC-60320-C19
8FT (2.4M)
DEC-19-20-3F
DEC-19-20-6F
DEC-19-20-8F
DEC-19-20-10F
C20 C19 20A/250V IEC-60320-C20 to IEC-60320-C19
3FT (0.9M)
6FT (1.8M)
8FT (2.4M)
10FT (3.05M)